Electrical Connections; Dip-Switches - DITEC OLLYC Manual Para La Instalacion Y La Manutencion

Automatización para puertas correderas internas
Ocultar thumbs Ver también para OLLYC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
4.

ELECTRICAL CONNECTIONS

Radar RER
Alimentazione (Vedi dati tecnici)
Power supply (See technical data)
4.1 Commands
Command
1
3
N.O.
1
4
N.O.
1
3
N.O.
1
4
N.C.
41
8
4.2 Outputs and accessories
Output
1
+
0 -
1
+
BL -
RER
4.3 Trimmer
TC
30 s
MAX=disabled
0 s
4.4 Signals
LED (two-color)
Green
Red

4.5 Dip-Switches

DIP1
Closure thrust.
Maintain the door wing in the closure position.
DIP2
Direction selection.
The opening direction is intended by viewing the
automation from the side being examined.
Function
OPENING
CLOSING
STOP
REVERSAL SAFETY
DEVICE
Value
24 V= / 0,3 A
24 V= / 0,5 A
Automatic closing time. From 0 to 30 s. Adjust the time that passes between the end
of the opening manoeuvre and the start of the automatic closing manoeuvre. The count
is reset when an opening command is given with the door open. Adjust the TC to the
maximum if automatic closing is not required.
24 V= power supply.
Safety contact 41 - 8 open.
Description
0 1 3 4 8 41 BL
RER
LED
ON
1 2
TC
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
The coincidence of an opening and closing command stops all movements.
Attention: when the contact opens again the door proceeds with the
interrupted manoeuvre.
The opening of the contact during the closure manoeuvre causes the
movement to invert (re-opening).
Accessories power supply.
Power supply output for external accessories.
Blocking device (OCLOKA).
Blocking is only activated when the door is closed.
Note: the door is released in the event of power failure and can be
manually operated.
RER Radar. Allows the connection of one or two RER radar.
Attention: set the radar dip/switch RER=DX.
ON
OFF
Disabled.
Left-hand opening for single door
wing automations.
Selection for double door wing
automations.
13
-
+ Uscita / Output 24 V= / 0,3 A
Apertura / Opening
Chiusura / Closing
Riapertura / Re-opening
Elettroblocco / Electric lock
Description
Description
Flashing
Encoder/automation fault.
Safety test failure.
ON
Enabled.
Right-hand opening for single
door wing automations
GB
OLLYC - IP1879