5.
ELECTRICAL CONNECTIONS
GB
Radar RER
Alimentazione (Vedi dati tecnici)
Power supply (See technical data)
5.1 Commands
Command
1
3
1
4
1
3
1
4
41
5.2 Output and accessories
Output
1
0
1
BL
RER
5.3 Trimmer
TC
30 s
MAX=disabled
0 s
5.4 Signals
LED (bicolor)
Green
Red
5.5 Dip-Switch
DIP1
Closure thrust. Maintain the door wing in the closure position. Disable.
DIP2
Direction selection. The opening direction is intended by
viewing the automation from the side being examined.
CIVIK - IP1953
OPENING
N.O.
CLOSING
N.O.
STOP
N.O.
REVERSAL SAFETY
N.C.
8
+
-
+
-
Automatic closing time. From 0 to 30 s. Adjust the time that passes between the end
of the opening manoeuvre and the start of the automatic closing manoeuvre. The count
is reset when an opening command is given with the door open. Adjust the TC to the
maximum if automatic closing is not required.
24 V= power supply.
Safety contact 41 - 8 open.
Description
0 1 3 4 8 41 BL
RER
TC
Function
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
The coincidence of an opening and closing command
stops all movements.
Attention: when the contact opens again the door pro-
ceeds with the interrupted manoeuvre.
The opening of the contact during the closure manoeuvre
causes the movement to invert (re-opening).
Value
Accessories power supply. Power supply output for ex-
24 V= / 0,3 A
ternal accessories.
Lock device (CIVIKLA). Lock is only activated when the
24 V= / 0,5 A
door is closed. Note: the door is released in the event of
power failure and can be manually operated.
Radar RER. Allows the connection of one or two RER ra-
dar. Attention: set the radar dip/switch RER=DX.
ON
Right-hand opening.
Selection for double door
wing automations.
22
-
+ Uscita / Output 24 V= / 0,3 A
Apertura / Opening
Chiusura / Closing
Riapertura / Re-opening
Elettroblocco / Electric lock
LED
ON
1 2
Description
Description
Flashing
Encoder/automation fault.
Safety test failure.
OFF
Enable.
Left-hand opening.