Culligan US-600 Instrucciones Para La Instalación Y El Funcionamiento

Culligan US-600 Instrucciones Para La Instalación Y El Funcionamiento

Filtro de agua debajo del fregadero
Ocultar thumbs Ver también para US-600:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Under-Sink Water Filter
Installation and Operating Instructions
Model US-600
Before proceeding with installation, choose the appropriate filter cartridge and install in
housing according to the cartridge replacement instructions (p. 2). See Filter Cartridge
Selection Guide on p. 3 to determine the best cartridge for your filtration needs.
Specifications
Pressure Range:
30–125 psi (2.1–8.6 bar)
Temperature Range:
40–100°F (4.4– 37.7°C)
Parts Included
• filter housing assembly with built-in mounting bracket and quick-connect fittings
inch (10 mm) tubing
3
8
• (2) quick-connect elbows
• housing wrench
• D-20 cartridge
Tools Required
screwdriver
file
pencil
pipe cutter or hacksaw
Precautions
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
Filter must be protected against freezing, which can cause cracking of the
filter and water leakage.
The rubber o-ring provides the water-tight seal between the cap and the
bottom of the housing. It is important that the o-ring be properly seated in the groove
below the threads of the housing or a water leak could occur.
Because of the product's limited service life and to prevent costly repairs or
possible water damage, we strongly recommend that the bottom of all plastic housings
be replaced every ten years. If the bottom of your housing has been in use for longer
than this period, it should be replaced immediately. Date the bottom of any new or
replacement housing to indicate the next recommended replacement date.
NOTE:
• For cold water use only.
• Make certain that installation complies with all state and local laws and regulations.
• The contaminants or other substances removed or reduced by the selected cartridge
are not necessarily in your water. Ask your local water municipality for a copy of
their water analysis, or have your private well tested by a reputable water testing
lab.
• After prolonged periods of non-use (such as during a vacation) it is recommended
that the system be flushed thoroughly. Let water run for 5–6 minutes before using.
• The filter cartridge used with this system has a limited service life. Changes in
taste, odor, color, and/or flow of the water being filtered indicate that the cartridge
should be replaced.
Optional Materials
faucet (FCT-1) for use with D-40 filter
cartridge
Technical Support: 1-800-721-9243 (M-F 8:00 am - 4:30 pm CST)
• Some harmless bacteria may attack cellulose media cartridges (such as the D-10).
If your cartridge seems to disintegrate or develops a musty or moldy odor, switch to
a synthetic media cartridge or call Technical Support.
Tested and Certified by NSF International against NSF/ANSI Standards 42/53 with
cartridges D-10, D-20, D-28, D-30 and D-40. See Performance Data Sheet in Manual
for specific claims.
Installation
NOTE:
• For standard under-sink installation on
PVC pipe).
• Please read all instructions and precautions before installing and using your US-600
under-sink filter.
• Install filter cartridge in filter housing before proceeding with installation (see Filter
Cartridge Replacement on p. 2).
• Numbered diagrams correspond with numbered steps.
1. (A) Turn off cold water supply and open nearest faucet to release pressure in pipes
before starting installation. Place a tray or towels under the cold water line to catch
excess water. (B) Select location under sink where filter is to be mounted. Use
mounting bracket as a template to mark screw locations. Mount filter in marked
location using mounting bracket.
NOTE: (C) Allow 1
inches (33 mm) clearance below housing to enable filter
1
2
cartridge changes.
2. Using a pipe cutter or hacksaw, remove a 3-inch (76 mm) section of pipe (A) from
the
inch (10 mm) cold water line. Deburr ends of remaining pipe with a file. (B)
3
8
Push a quick-connect elbow onto each end of remaining cold water line. Be sure to
push elbow onto pipe until you hit a hard stop.
3. Determine the lengths of tubing needed to connect the inlet and outlet sides of
filter to the quick-connect fittings on the cold water line. Measure tubing short
enough to prevent kinking. Cut the tubing squarely between the closest set of
black guide arrows. Assemble as shown in Figure 3 on page 2, inserting tubing into
appropriate inlet or outlet quick-connect fitting until it stops (inlet and outlet are
marked "IN" and "OUT" on cap).
NOTE: When cut between a set of black guide arrows, the tubing should be pushed
1
A
B
C
1
"
1
2
inch (10 mm) cold water line (copper or
3
8
2
B
A
145427 Rev M 06/07

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Culligan US-600

  • Página 1 • For standard under-sink installation on ⁄ inch (10 mm) cold water line (copper or PVC pipe). • housing wrench • Please read all instructions and precautions before installing and using your US-600 • D-20 cartridge under-sink filter. Tools Required Optional Materials •...
  • Página 2: Filter Cartridge Replacement

    Replacement Parts 1 01019191 OR-233 o-ring 2 01019199 SW-5 housing wrench not shown For replacement parts, contact your nearest retailer or call Culligan Consumer Services at 1-888-777-7962. Maintenance Contact your area retailer or local water treatment professional for replacement cartridge pricing.
  • Página 3: Performance Data

    2.0 mg/L±10% ≥50% Particulates at least 10,000 Performance Data ≥85% (0.5– <1m) particles/mL Class I Model US-600 Standard 53 Health Effects Important Notice: Read this performance data and compare the capabilities of this sys- Minimum Cysts† 99.95% 99.99% 99.99% 50,000/L tem with your actual water treatment needs.
  • Página 4 = As noted for each individual Pressure: = 30–125 psi (2.1-8.6 bar) workmanship only for five full years from original date of delivery. Culligan will replace any part which in Cul- filter cartridge Temperature = 40–100°F (4.4–37.7°C) ligan’s opinion is defective, unless: (1) any part of the system has been subjected to any type of tampering, Inlet Pressure = 60 psi (4.1 bar)
  • Página 5: Especificaciones

    • Por favor lea todas las instrucciones y precauciones antes de instalar o de usar el • cartucho D-20 sistema filtrante US-600 debajo del fregadero. • Instale el cartucho filtrante en el pocillo antes de proceder con la instalación (mire la...
  • Página 6: Reemplazo Del Cartucho Filtrante

    Por piezas de reemplazo, póngase en contacto con el minorista más cerca a usted o llame gratis al departamento de servicios Culligan 1-888-777-7962. Ajustes y Reparaciones Contacte al minorista más cercano o un profesional para el tratamiento de agua por el precio del los...
  • Página 7: Reparaciones

    ≥50% Particulas Datos de Funcionamiento por lo menos (0.5– <1m) 10,000 ≥85% Modelo US-600 particulas por mL Clase I Norma 53 Efectos De Salud Aviso importante: lea estos datos de funcionamiento y compare la capacidad de este Quistes† Minimo 50,000/L 99.95%...
  • Página 8: Condiciones De Prueba

    Culligan reemplazará cartucho filtrante cualquier pieza la cual en la opinión de Culligan es defectuosa, al menos que: (1) cualquier pieza del sistema Presión = 30–125 psi (2.1-8.6 bar) haya sido sujetado a cualquier clase de interferencia, alteración, o uso inapropiado después de entrega, o (2)

Tabla de contenido