BRS-LCi
9 Maintenance and cleaning
Regular and lasting maintenance and cleaning are the prerequisite of a long life and a trouble-free function.
In doing so, observe the following:
Risk of injury due to unexpected start-up.
The following instructions must be adhered to for the entire duration of maintenance, servicing, mounting,
dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
NOTICE
• Maintenance and cleaning work may only be carried out by qualified personnel
• Always wear your personal protective equipment when performing maintenance and cleaning work.
9.1 Maintenance intervals
NOTICE
• The maintenance intervals given are recommended values and refer to single-shift operation.
The cleaning station BRS-LCi is virtually maintenance-free. However, it is necessary to regularly clean and
evaluate the mechanically stressed parts in order to maintain its value and to guarantee its full ability to
function.
Check the following:
Weekly
• Check the condition of the milling cutter.
• Clean the clamping unit or the milling cutter.
Tab. 10
Maintenance intervals
BAL.0149.0 • 2017-05-17
DANGER
DANGER
(in Germany see TRBS 1203).
9 Maintenance and cleaning
Monthly
• A monthly basic cleaning is recommended, and necessary
in case of extreme working conditions.