Digital clamp meter
• Insert black probe to the COM jack, insert red probe to the INPUT jack.
• Place measuring switch in position
• Press the FUNC key to switch to circuit continuity measuring state.
• Connect the probe to the both ends of circuit to be tested for
measurement.
• If the resistance of circuit to be measured is less than 40Ω , the meter's
built-in buzzer may sound.
• LCD will show readings.
Note: If the probe is open or circuits resistance to be tested is more than
400Ω, the display will show "0L".
Capacitance Μeasurement
Warning
Electric shock hazard.
To avoid electric shock, before measuring capacitance, discharge
capacitance completely.
• Insert the black probe to the COM jack and the red probe to the INPUT.
• Place measuring switch in position
• After discharging capacitor completely, connect the probe to the ends of
capacitor to be tested.
• LCD will show readings.
Note: When measuring bulk capacitor, stable readings will take some time.

Temperature Measurement

• Insert the temperature probe into the COM, INPUT jack.
• Place measuring switch in position Temp.
• LCD will show readings.

NCV (non-contact voltage detection)

• Turn the meter to NCV grade
• Place the meter top close to the condtor. When test voltage is greater
than 110 Vac (RMS), the meter induction voltage indicator will turn on and
buzzer will give dripping alarm sound.
Note:
1. Even there is no indication, voltage may still exist. Don't use non-contact
voltage detector to judge whether there is voltage in the wire. Detection
Instructions manual |
34
.
.