• Retract the lips, cheeks and tongue to prevent contact
with the insert tip whenever it is placed in the patient's
mouth.
3.3 Precautions for Air Polishing
Procedures
• Only set the air polishing powder flow control to the
maximum position (H) when it is necessary to remove
particularly difficult stains. Return the powder flow
control to the medium position upon the completion
of the procedure.
• Avoid prolonged or excessive use on restorative dental
materials.
• Avoid prolonged use on cementum or dentin.
• Avoid prolonged use on polished metal surfaces
Section 4: Infection Control
4.1 Infection Control Information
Reference Card
For your convenience, an Infection Control Information
reference booklet, has been included with your Cavitron
JET Combination System. If your booklet is missing or mis-
placed, you can request a replacement in the U.S. by calling
Customer Service at 1-800-989-8826 Monday through Friday,
8:00 AM to 5:00 PM (Eastern Time) For other areas, contact
your local DENTSPLY representative.
4.2 General Infection Control
Recommendations
• As with all dental procedures, use standard personal
protection equipment (i.e., wear face mask, eyewear
or face shield, gloves and protective gown).
• As with high speed handpieces, and other dental devices,
the combination of water and ultrasonic vibration from
Section 5: Installation Instructions

5.1 General Information

If the installation of your Cavitron
performed by someone other than trained DENTSPLY
personnel, care should be taken to observe the following
requirements and recommendations.

5.2 Water Line Requirements

• A water supply line with user-replaceable filter is factory
installed on you Cavitron JET Combination system. Do
not disconnect the water supply line. See 9.0 System
Care for filter replacement instructions.
ENGLISH
4
JET Combination System is
®
Dealer
as a matte finish may result.
• Patients who are on a restricted sodium diet, or have
severe respiratory illness, should consult their physician
before undergoing air polishing prophylaxis procedures.
• Patients wearing contact lenses should remove them prior
to air polishing treatment.
• JET Airpolishing Insert nozzles that have been bent,
damaged or re-shaped, are susceptible to in-use breakage
and should be discarded and replaced immediately.
• Check O-ring and threads on powder bowl cap to ensure
a tight seal. If O-ring or threads have worn, replace
immediately. Residual prophy powder in threads can
result in excessive wear and disengagement of the cap
during unit operation.
your Cavitron
JET Combination System will create
aerosols. With proper technique, much of the Cavitron
JET Combination System's aerosol dispersion can be
effectively controlled and minimized. Please carefully
follow the procedural guidelines in this manual
cregarding the use of your System.
• For maximal operator and patient safety, carefully follow
the Infection Control Information procedures detailed
on the reference card accompanying your System.

4.3 Water Supply Recommendations

It is highly recommended that all dental water supply systems
conform to applicable CDC (U.S. Centers for Disease Control
and Prevention) and ADA (American Dental Association)
standards, and that all recommendations be followed in terms
of flushing, chemical flushing, and general infection control
procedures. See sections 5.2 and 9.
• Incoming water supply line pressure to the System must
be 25 psi (172 kPa) to 60 psi (414kPa). If your dental
water system's supply line pressure is above 60 psi (414
kPa), install a water pressure regulator on the supply
line to your Cavitron
• A manual shut-off valve on the dental water system
supply line should be used so that the water can be
completely shut-off when the office is unoccupied.
• In addition to the water filter supplied, it is recommended
that a filter in the dental water system supply line be
installed so that any particulates in the water supply
will be trapped before reaching the System.
• After the above installations are completed on the dental
JET Combination System.