Heating During The Transition Period; Regulation Of Combustion Air; Combustion Air Slide Valve; Fire Grate - Olsberg Turia Lina Compact 23/625 Manual De Instrucciones

Ocultar thumbs Ver también para Turia Lina Compact 23/625:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Combustion air slide valve

Operating lever for combustion air supply
● Operating lever on „0":
all slide valves closed
● Operating lever on „I":
Secondary slide valve completely open /
Primary air slide valve completely closed

Regulation of combustion air

● Operating lever on „II":
Secondary slide valve completely open /
Primary air slide valve completely open
Position of operating lever:
„II" ..Ignition position, max. heat output
"I" - "II" ..Nominal heat output with lignite briquettes
„I" ...Nominal heat output with billet wood
„I" ...Nominal heat output with wood briquettes
„0" ..Obtain glow
● As the secondary air also contributes to the cleanli-
ness of the glass pane, the operating lever should be
set on "I" minimum. This also applies in the event of
low-load operation.
● When not operating the lever should be set on "0", to
reduce the cooling down of the room.

Fire grate

be opened or closed to move the ash from the com-

Heating

grate back and forth.
● Primary air can only enter the combustion chamber
● Only place the quantity of fuel required to achieve
the heating requirement.
For a nominal heating output 5 kW:
- max. 1,5 kg billet wood; burning time >45 min
- max. 1,3 kg wood briquettes; burning time >45 min
- max. 2 lignite briquettes; burning time >60 min
For max. heat output allowed:
- max. 3 kg billet wood
- max. 3 kg wood briquettes
- max. 4 lignite briquettes
● Open the combustion chamber door slowly after
adding new fuel, as otherwise the combustion gas-
es can escape.
● Empty the ash pan or combustion chamber in good
time. Otherwise it is possible for the combustion air
intake to be blocked or for the grate to be damaged.
● Only remove the ash pan to empty it.
● Clean the ash pan compartment regularly after re-
moving the ash pan to remove any ash that may
Operating lever for the fire grate

Heating during the transition period

have been spilled (e.g. use a vacuum cleaner).
● With the help of the operating lever the fire grate can
Attention: Any stove and ash residues must have
been left to cool before being removed.
bustion chamber to the ash pan by pushing the fire
if the fire grate is set on open position.
Prerequisite for the stove to function well is the correct
delivery pressure (chimney draught). This very much
depends on the external temperature. Therefore, if the
external temperatures are high (above 16°C) the deliv-
ery pressure can be disrupted.
What to do?
● Open the combustion air slide valve complete.
● Only put on a small quantity of fuel.
● Frequently stoke the ash.