Goulds Pumps
ApplicATionS
• Residential, commercial or agricultural pressure wash
• Reverse osmosis
• Evaporative cooling systems/misters
• Booster service
• Spray systems
• Water circulation
• Filtration
• HVAC
• General purpose pumping
WARninGS
• Pumps used on open spray applications must be plugged into
electrical service which is protected by a Ground Fault Service
Interruptor. Failure to do so may result in serious personal
injury or death and property damage.
• Do not run pump dry.
• Do not run pump below minimum flow.
• If positive suction pressure is not available, be sure pump and
suction line (with foot valve) are primed before starting pump.
Residential and Commercial Water
SpEciFicATionS
Pump:
• Maximum suction (inlet) pressure: 75 PSI.
• Maximum Liquid Temperature: 160º F (71º C).
• Rotation: Clockwise when viewed from motor end.
• Maximum lift with foot valve: 10 ft. check NPSH curve.
Motor:
• NEMA standard 56J frame.
• Open drip proof or totally enclosed fan cooled enclosures
available as standard. Consult factory for other options.
• 60 Hz, 3500 RPM. Single phase (115/230 V), three phase
208-230 (3 HP , 230 V) or three phase (208-230/460 V).
• Single phase motors have built-in capacitor and overload with
automatic reset.
Note: For three phase motors, overload protection must be
provided in starter unit. Starter and heaters must be ordered
separately.
MATERiAlS oF conSTRUcTion
Item
Description
1
Motor Adapter
2
Mechanical Seal
3
Shaft Coupling
4
Impeller/Diffuser
5
Bowl
6
Discharge Head
304 Stainless Steel
7
Hex Shaft
8
Casing
1
4
8
6
7 5
3
2
Material
Cast Iron or Cast 304 Stainless Steel
0=Carbon/Ceramic/BUNA
3=Carbon/Silcar/EPR
4=Carbon/Silcar/Viton
Stainless Steel
Engineered Composite
304 Stainless Steel
Cast Iron or Cast
Stainless Steel
304 Stainless Steel
2