Introduction
Before installing the collective protection, the load-bearing capacity of the roof /
substructure must be checked. In case of doubt seek the advice of a structural
engineer! The technical building regulations must be complied with. All variants of
collective protection run as standard parallel to the installation surface or the
mounting surface! Do not make any changes to the edge protection equipment
deviating from these instructions and use original parts of the collective protection
only.
SAFETY INSTRUCTIONS:
®
LUX-top
G-T
may only be installed by qualified persons, who are familiar with these user
instructions and the local safety rules and regulations and are physically and mentally suitable
for the task. Health restrictions (e.g. cardiovascular problems, medication) can endanger
safety when working at heights.
®
The
LUX-top
G-T
who are at risk of falling in areas not accessible to the public.
®
LUX-top
G-T
is suitable for installation on adequately load-bearing bitumen, membrane and
concrete roofs.
The standing area of the
substances, algae, snow and ice.
Use of the collective protection for any purpose other than that for which it is intended, e.g. by
hooking on undefined loads or lifting or lowering loads on a rope, e.g. building materials, is
not allowed.
®
The
LUX-top
G-T
national lightning protection regulations. Use as an arrester device is not permitted!
In case of sloped surfaces and roofs, snow guards must be installed to prevent loading of the
®
LUX-top
G-T
system with snow loads!
Use of the
LUX-top
the edge of the roof (minimum height 50 mm above the guardrail standing area).
Exception:
LUX-top
Use in case of frost risk or frost conditions, which result in a hazard, is prohibited.
In case of wind strengths extending beyond normal values (wind strength 10), the aluminium
collective protection may not be used.
The place of installation may not be higher than 40 m above the surrounding ground.
The manufacturer must be contacted in case of any uncertainty during installation or use of
®
the
LUX-top
G-T!
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection solutions – www.lux-top-absturzsicherungen.de
aluminium collective protection is used solely to secure authorised persons
®
LUX-top
G-T
must be plane, free from loose materials, any slippery
must be integrated into the lightning protection in accordance with the
®
G-T
system requires the presence of a load-bearing parapet/upstand at
®
G-T DIREKT/DIREKT WD
Page 1 Version 05/2019
with fixing on the substrate.