General Assembly And Installation Requirements - ST Quadrat LUX-top G-T Instrucciones De Montaje Y Uso

Protección colectiva de aluminio para el uso en cubiertas planas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

General assembly and installation requirements:

max.
0.40 m
Start, end and
corner post
4 slabs @ 11.5 kg
* max. 0.50 m in EN ISO 14122-3
 Openings between the edge protection systems and other constructions must be as small as
possible, however, must not exceed 120 mm for principle guardrails and 20 mm for the
toeboard.
 Only concrete paving slabs 50x25 cm with a maximum thickness of 5 cm and at least 11.5 kg
weight each may be used as weighting material.
®
 The
LUX-top
G-T / LUX-top
end post. These must be equipped with a double weight (see schematic diagram).
 During the preparation phase: Roughly spread the basic elements, counterweight holders and
concrete slabs along the length of guardrail to be installed in line with the installation
requirements.
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection solutions – www.lux-top-absturzsicherungen.de
max.
2.0 m
Clear size
max. 0.47
m
*
Clear size
max. 0.47
m
*
L = 1.30 m
W = 0.55
m
®
G-T ECO
Page 16 Version 05/2019
max.
max.
0.40 m
2.0 m
Intermediate post
2 slabs @ 11.5 kg
must always consist of at least one start and one
A diagonal member is
required in each
section / module!
Parapet height min. 50 mm!
A toeboard is required where parapet
heights are less than 150 mm!
Figure by way of
example
H = 1.15 m

Publicidad

Tabla de contenido
loading