● Suitable for Class II, Division 2, Groups B, E, F and G outdoor (Type 4X), Class III (CSA
● Temperature code T6 at an ambient of 40°C
ATEX installation
Read, understand and follow all safety instruction on the electronic media provided. This
equipment is rated for use in explosive atmospheres as stated below and must be installed
according to the 1010-422 installation drawing provided on the media. Failure to install the
equipment in the prescribed manner will result in unsafe operation. Follow all regional safety
laws when operating this equipment. When properly installed the equipment meets the
following ATEX ratings as stated in EC-Type Examination Certificate KEMA03ATEX2133
Transmitter
● IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid,
Sensors
● IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid,
See also
Contacts (http://www.siemens.com/processinstrumentation/contacts)
FUS1010 IP65 NEMA 4X
Operating Instructions, 7/2010, A5E03086486-02
only)
II 2 (1) G Ex d [ia] IIB+H2 – Category 2 Transmitter located in Zone 1 hazardous area
with intrinsically safe circuits of category Ex ia, which can be connected to Category 1
Sensors for use in potentially explosive atmosphere containing gases
rating of water jets
II 1 G Ex ia IIC T5 – Category 1 Sensors located in Zone 1 hazardous area with
intrinsically safe circuits of category Ex ia for use in potentially explosive atmosphere
containing gases
rating of water jets
Introduction
1.3 Safety Notes