THERAPRO HR90
Parameters marked with an * are described in more detail
below.
Par. Setting
1
Language setting
German
1
2
English
3
Danish
4
Swedish
5
Norwegian
6
Finnish
2
Preset time programs *
0
Week program 1 "At home all day"
1
Week program 2 "Lunch break at home"
2
Week program 3 "Part-time work"
3
Backlight *
0
Deactivated
Activated
1
4
Summer/winter time changeover
0
No automatic changeover
Automatic changeover
1
5
0
Duration of the window function *
30
Window function not active
...
Valve opens at the latest after 30 minutes
90
...
Valve opens at the latest after 90 minutes
6
Sensitivity of the window function during
dropping room temperature *
0.2
0.2 (sensitive)
...
...
2.0
2.0 (less sensitive)
Factory setting: 0.4
7
Sensitivity of the window function during
rising room temperature *
0.1
0.1 (sensitive)
...
...
2.0
2.0 (less sensitive)
Factory setting: 0.2
8
Setting the valve stroke *
0
Standard valve stroke
1
Full-stroke mode
9
Temperature representation in the display
0
*
Set/programmed temperature (setpoint
temperature)
1
Measured room temperature
10
Upper temperature limit
16
The room temperature cannot be set
17
higher than the specified upper
...
temperature limit (Max Limit).
30
Factory setting: 86 °F
11
Lower temperature limit
5
The room temperature cannot be set
6
lower than the specified lower
...
temperature limit (Min Limit).
Factory setting: 41 °F
15
12
Optimization function *
No optimization
0
1
Optimum start
2
Optimum start/stop
13
Temperature offset *
3
To adjust the temperatures measured by
...
the radiator controller and in the room
-3
Factory setting: 32 °F
33-00084EFS—02
Table 1.
Meaning
Table 1. (Continued)
Par. Setting
14
Battery type
Alkaline
0
1
Lithium
2
NiMH (rechargeable batteries)
15
Display valve position *
0
No display of the valve position
1
Momentary display of the valve position
16
Valve exercise day *
Monday
0
1
Tuesday
2
Wednesday
3
Thursday
4
Friday
5
Saturday
6
Sunday
7
Off
17
Window open function *
0
Off (no window function)
Auto (corresponding to Parameters 5-7)
1
2
Cabled (with floating window contact)
18
Temperature unit
0
°Celsius
1
°Fahrenheit
19
Restore to factory setting
No reset
0
1
Reset only the basic settings
2
Reset only the time program
3
Reset all
Changing parameters
1. Keep the PROG button pressed for at least 10 sec-
onds until Parameter 1 flashes (left-hand digit).
M35647
The right-hand digit shows the current setting. The
parameter is displayed additionally in plain text. For
example, the display 1 1 stands for Parameter 1
(language) with Setting 1 (German).
2. Use the adjustment dial to select the desired
parameter (left-hand digit).
3. Press the OK button to edit the parameter.
The current setting of the parameter flashes (right
hand digit).
4. Use the adjustment dial to set the desired setting
(right-hand digit) and confirm with OK.
The parameter being edited flashes (left-hand digit).
5. For the further parameters repeat Steps 2 to 4.
6. Use the AUTO button to return to automatic mode.
Description of the parameters
Parameter 2 –Selecting the preset time
programs
• Week program 1 (factory setting, 2 setpoints):
Mo – Su (1 – 7) at home all day
This time program is described in Section 8.
• Week program 2 (6 setpoints):
Mo – Fr (1 – 5) lunch break at home
Sa – Su (6 – 7) like Week program 1
8
Meaning