GB
Technical details/Function/Installation
Technical details
Technical details
Technical details
Maximum head
Maximum flow
Maximum Liquid Temp.
Maximum suction depth
Power supply cable
Output
Accumulator
Function
Warning: This jet pump includes a feature which pro-
tects it against splashing and must only be placed in dry
areas. Never place or use the water pump in the rain or
in a damp location.
Warning: This Jet Pump must not be used with inflam-
mable or dangerous liquids.
Warning: Avoid using the jet pump when it is empty.
Warning: This Jet Pump must only be used with clean
water. Its range of applications includes the watering of
gardens, the water supply to a house or the sprinkling
watering system for gardens and crops.
This Jet Pump must not be exposed for long periods
of time to impurities, sand, stones, sticky substances,
etc., or mixed with the transported goods. Since the
transported goods may contain corrosive chemical
substances, special attention must be given to avoid
the influence of these on the body of the Jet Pump. Its
use to provide drinking water is not permitted.
Danger: If this Jet Pump is used in a swim-
ming pool, pond or similar location, you need
to install a special cut off switch to protect
it from electrical discharges (earth leakage
circuit breaker) and keep it running to gua-
rantee the safety and reliability of the pump.
Furthermore, the Jet Pump must be placed
on a stable surface to prevent it from falling.
Sego Tank 600
600W - 0,8CV
34 m
50 l/min - 3 m
/h
3
+35ºC
7 m
1,2 m
1"
20 litros
Installation
General description
Danger: Always unplug the Jet Pump from the power
supply during the installation.
Warning: During the installation, the equipment must
be kept in a dry and aired area, at a room temperature
of under 40ºC.
Danger: If its action results in an excess of pumped
water and the subsequent flooding of the irrigation
area, a series of precautionary measures may be taken
(for example, the installation of a device to discharge
the excess water, an alarm, an auxiliary pump, a water
tank, etc.). Our company, however, is not responsible
for any loss incurred under these circumstances.
Before operating the Jet Pump, it must be inspected as
a safety precaution to ensure that there is no damage
to the cable or plug. The use of a water pump in a bad
condition is strictly forbidden.
Electric connection
Danger: The electrician responsible for the installation
must check that the electricity connection complies
with the current standards, even the earth connector.
Danger: You need to check the rated current of the
electric connection with a safety switch; this must be =
30mA (according to the DIN VDE 0100T739 standard).
8
G.P. Tank 1200
1200W - 1,6CV
46 m
63 l/min - 3,8 m
/h
3
+35ºC
7 m
1,2 m
1"
20 litros