Before start-up

12.1 Connecting the torch

 Connect the central connector 17 of the
torch to the central socket 11.
11
17
Abb. 2:
Connecting the torch

12.2 Connecting the ground cable

 Connect welding return cable 18 to con-
nector 10 and secure it by turning it clock-
wise.
10
18
Abb. 3:
Connecting the ground cable
- 42 -

12.3 Fastening the ground clamp

Abb. 4:
Correct
 Attach the ground clamp immediately be-
side the welding point so that the welding
current will not try to find its own return
path through machine parts, ball bearings
or electric circuits.
 Connect the ground clamp firmly to the
welding bench or the workpiece.
Abb. 5:
Incorrect
‰ Do not place the ground clamp on the
welding machine or the gas cylinder; oth-
erwise the welding current will be carried
via the protective conductors and it will
destroy these.