Default value
750
Unit
mbar
EEPROM
yes
Valor de ajuste de histéresis h1 de los eyectores
Parameter
101 (0x0065)
Description
Hysteresis h1 for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read/write
Value range
(H1-H2) >= h1 > 10
Default value
150
Unit
mbar
EEPROM
yes
Valor de ajuste para punto de conmutación H2 de los eyectores
Parameter
102 (0x0066)
Description
Setpoint H2 for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read/write
Value range
(H1-h1) >= H2 >= (h2+2)
Default value
550
Unit
mbar
EEPROM
yes
Valor de ajuste de histéresis h2 de los eyectores
Parameter
103 (0x0067)
Description
Hysteresis h2 for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read/write
Value range
(H2-2) >= h2 >= 10
Default value
10
Unit
mbar
EEPROM
yes
ES · 30.30.01.01598 · 02 · 01/19
Interfaces