schmalz SCTMi Instrucciones De Funcionamiento página 39

Ocultar thumbs Ver también para SCTMi:
Tabla de contenido

Publicidad

Value range
0x00 = control is not active, H1 in hysteresis mode
0x01 = control is not active, H1 in comparator mode
0x02 = control is active
0x03 = control is active with supervision of leakage
0x04 = control is active, continuous succing disabled
0x05 = control is active with supervision of leakage, continuous succing disa-
bled
Default value
0x02 = control is active
Unit
-
EEPROM
yes
Modo de soplado de los eyectores
Parameter
110 (0x006E)
Description
Blow-mode for ejectors
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint8
Length
16 Byte
Access
read/write
Value range
0x00 = externally controlled blow-off
0x01 = internally controlled blow-off – time-dependent
0x02 = externally controlled blow-off – time-dependent
Default value
0
Unit
-
EEPROM
yes
Tensión de alimentación del sensor
Parameter
66 (0x0042)
Description
Primary supply voltage
Index
0: actual value as measured by the device
1: min. value since last power-up
2: max. value since last power-up
Datatyp
uint16
Length
6 Byte
Access
read only
Value range
-
Default value
-
Unit
0.1 V
EEPROM
no
Tensión de alimentación del actuador
Parameter
67 (0x0043)
Description
Auxiliary supply voltage
Index
0: actual value as measured by the device
1: min. value since last power-up
ES · 30.30.01.01598 · 02 · 01/19
Interfaces
39 / 72

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

ScpstProfinetEthernet/ipEthercat

Tabla de contenido