Default value
-
Unit
-
EEPROM
yes
Contador reseteable de ciclos de aspiración de los eyectores
Parameter
143 (0x008F)
Description
Erasable vacuum-on counter for ejector
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint32
Length
64 Byte
Access
read only
Value range
0 ... 999.999.999
Default value
-
Unit
-
EEPROM
yes
Contador reseteable de ciclos de ventilación de los eyectores
Parameter
144 (0x0090)
Description
Erasable valve operating counter for ejector
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint32
Length
64 Byte
Access
read only
Value range
0 ... 999.999.999
Default value
-
Unit
-
EEPROM
yes
CM de los eyectores
Parameter
146 (0x0092)
Description
Condition Monitoring of ejector
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint8
Length
16 Byte
Access
read only
Value range
Bit 0 = Valve protection active
Bit 1 = Evacuation time greater than limit
Bit 2 = Leakage rate greater than limit
Bit 3 = H1 not reached in suction cycle
Bit 4 = Free flow vacuum too high
Bit 5 = Manual Mode Active
Default value
0
Unit
-
EEPROM
no
ES · 30.30.01.01598 · 02 · 01/19
Interfaces
45 / 72