Interfaces
Default
-
value
Unit
-
EEPROM
no
NFC Status
Parameter
139 (0x008B)
Description
NFC Status
Index
-
Datatyp
uint8
Length
1 Byte
Access
read only
Value range
0x00: data valid, write finished successfully
0x23: write failed: write access locked
0x30: write failed: parameter(s) out of range
0x41: write failed: parameter set inconsistent
0xA1: write failed: invalid authorisation
0xA2: NFC not available
0xA3: write failed: invalid data structure
0xA5: write pending
0xA6: NFC internal error
Default value
-
Unit
-
EEPROM
no
Contador total de ciclos de aspiración de los eyectores
Parameter
140 (0x008C)
Description
Vacuum-on counter for ejector
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint32
Length
64 Byte
Access
read only
Value range
0 ... 999.999.999
Default value
-
Unit
-
EEPROM
yes
Contador total de ciclos de ventilación de los eyectores
Parameter
141 (0x008D)
Description
Valve operating counter for ejector
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint32
Length
64 Byte
Access
read only
Value range
0 ... 999.999.999
44 / 72