APPLIANCE DESCRIPTION
Sturdy stainless steel structure with 4 feet that can be
adjusted in height. External coating made in 18/10
chromium-nickel steel. The special steel plate has a smooth
or ribbed surface equipped with side and back steel
splashguards. It's also fitted with a stainless steel gravy
collection tray. The plate is heated by tubular chromium-
plated steel burners resistant to thermal or mechanical
stresses. The pilot burner is equipped with fixed injectors.
The temperature can be regulated by means of proper taps
equipped with safety devices. Our griddles are available in
the smooth or ribbed plate versions.
The G7FL8B-2 • G7FL8B-2/CR • G7FR8B-2 • G7FM8B-2 • G7FL8M-2 •
G7FL8M-2/CR • G7FR8M-2 • G7FM8M-2 • G9FL8M-2 • G9FL8M-2/CR •
G9FL8M-2/CPD • G9FR8M-2 • G9FM8M-2 • SG9FL8M-2 • SG9FL8M-2/
CR • SG9FL8M-2/CPD • SG9FR8M-2/CPD • SG9FM8M-2/CPD •
LXG9FL8-2/CPD • LXG9FR8-2/CPD • LXG9FM8-2/CPD • SG7FL8B-2/
CPD • SG7FM8B-2/CPD • SG7FR8B-2/CPD models are equipped
with separate cooking areas with independent controls to
regulate the temperature.
PREPARATION
Location
The appliance should be installed in a well ventilated room
and, if possible, under a range hood. The appliance can
be installed on its own or alongside other equipment. If
the appliance is to be installed near inflammable walls, a
minimum distance of 150 mm around the sides and back
should be maintained. If this is impossible, take the proper
measure to ensure that the installation is safe, such as
fitting tiles or heat-reflecting material to the walls. Place the
appliance on a table or on a board made of non-flammable
material. Before connecting the appliance to the gas supply,
check the data plate to make sure that the appliance is
fitted for the type of available gas. If not, see the paragraph
"Running appliances on other types of gas".
Law provisions, technical regulations and directives
Before installing, check that the following provisions are
met:
- UNI CIG 8723 regulation
- building regulations and local fire prevention measures;
- accident prevention regulations in force;
- local Gas Board regulations;
- CEI provisions in force;
- Fire Brigade provisions.
ASSEMBLY
Assembly, installation and maintenance must all be done by
contractors authorized by the local Gas Board in accordance
with the regulations in force. Before doing anything else,
contact your Gas Board.
Installation procedure
ENGLISH
INSTALLATION INSTRUCTIONS
To level the appliance correctly, adjust the height of the four
adjustable feet.
Gas connection
The 3/8" G or ½" G gas pipe union can either be permanently
fixed or detached by using a standard adaptor. If a flexible
hose is used, it must be stainless steel and in conformity with
regulations. After completing the connection, check for leaks
by using a special leak-detector spray.
Exhaust system
The appliances must be positioned in locations adapted
with a system for discharging the products of combustion
in respect of how much is prescribed by the norms of the
installation; such a system must comply with installation
regulations. Our appliances are classified as type "A" gas units
(see the "TECHNICAL DATA" table). They are not designed
for the connection to a line for the discharge of products of
combustion.
These appliances must discharge the products of combustion
into appropriate hoods, or similar devices, connected to a
flue of proven efficiency, or they may be connected directly
to an outdoor vent.
If such an arrangement is not possible, the unit may be
connected to an air exhaust system which leads directly
outdoors, having a capacity no lower than required; see the
"TECHNICAL DATA" table, plus the air exchange necessary, in
order to make operators comfortable.
Before installation
Before installing the appliance, remove the protective
wrapping. Thoroughly clean the work-surface and the
outside of the appliance with lukewarm water and detergent,
using a soft cloth. Dry with a clean cloth.
Start-up
Before starting the appliance, make sure that its specifications
(category and type of gas used) match those of the family
and group of the gas available locally.
If not, adapt the appliance to the gas family or group
required (see paragraph "Running the appliance on other
types of gas"). Carry out the start-up according to the User's
Instructions.
Testing power rating
Use the nozzles for rated output on the appliances.
Capacity can be of two types:
- rated output, as given on the data plate;
- reduced.
These nozzles are shown in the table "BURNERS".
The gas supply pressure must always be within the ranges
The appliance will not work outside the above pressure
thresholds.