PROBLEMS AND SOLUTIONS
PROBLEM
THE MOTOR DOES NOT
START
THE PUMP DOES NOT
SUCK
INSUFFICIENT FLOW-RATE Suction height too high
THE THERMAL SWITCH
TURNS OFF THE PUMP
If the fault cannot be removed, contact the authorised service department nearest to you. To avoid
any damage during transport, PLEASE CARRY OUT THE SHIPMENT WITH ORIGINAL PACKAG-
ING.
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
DISCONNECT THE HYDRAULIC POWER DURING ANY MAINTENANCE
OPERATION ON THE UNIT
CAUSE
No mains voltage
Pump impeller locked
Thermostat disconnected
Suction valve outside the fluid
Pump chamber without fluid
Air in the suction hose
No hermetic suction valve
Dirty suction filter
Maximum suction height exceeded
Dirty suction filter
Fluid level lowers quickly
Pump flow-rate reduced by foreign
objects
Overload motor. Too much friction
caused by foreign objects
SOLUTION
Check the voltage
Remove the hydraulic part and
check if the impeller is free to
rotate. Reinstall carefully
Place the valve into the fluid
(minimum 30 cm below the
level)
Pour the fluid into the suction
fitting
Check the seal of suction hose
Clean the suction tube
Clean the filter
Check suction height
Check suction height
Clean the filter
Place suction valve lower
Clean the pump and replace
worn parts
Remove foreign objects Wait
until thermal protection switch
trips again