- EN -
8.1
Cleaning the pump
How to proceed:
J
1. Screw off the stepped hose adapter.
2. Remove screws.
– The screws are used as transport protection and not required for operation.
3. Actuate the engagement hook and fold up the strainer top casing.
4. Remove pump.
5. Remove screws.
6. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
7. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will
not be crushed when closing the filter housing.
9
Wear parts
• Impeller unit
10
Spare parts
The use of original parts from OASE ensures
continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings
and spare parts.
11
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are ex-
pected.
How to correctly store the unit:
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.
12
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accord-
ance with the regulations.
13
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the
return system provided for this purpose.
26
www.oase.com/spareparts