Technical Characteristics Of The Product - Nice MOON MC824H Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNINGS: • All technical characteristics stated refer to an ambient temperature of 20°C (±5°C). • Nice S.p.a reserves the right to modify the product at any time
while maintaining the same functionalities and intended use.
Power supply
Nominal power absorbed from mains
Power absorbed from mains
"standby - All" operation
(including receiver)
Power absorbed from control panel
24 Vdc side with "standby - All"
operation (including receiver)
Flashing light output
Courtesy light output
Electric lock output
Gate open light output
Maintenance light output
BLUEBUS output
STOP Input
PP input
OPEN input
CLOSE input
Radio connector
Radio AERIAL input
Programmable functions
Functions in self-learning mode
Operating temperature
Use in particularly acid, saline or
potentially explosive atmospheres
Protection rating
Dimensions (mm)
Weight (kg)
8 – English

TECHNICAL CHARACTERISTICS OF THE PRODUCT

230 Vac (+10% -15%) 50/60 Hz
200 W
2 W
less than 100 mW
1 "LUCYB" type flashing light (12 V, 21 W lamp)
1 max. 24 V max. 4 W lamp (output voltage may vary between -30% and +50%, output may also control small relays)
1 max. 12 Vac max. 15 VA electric lock
one 24 V max. 4 W lamp (output voltage may vary between -30% and +50%, output may also control small relays)
one 24 V max. 4W lamp (output voltage may vary between -30% and +50%, output may also control small relays)
1 output with maximum load 15 Bluebus units (maximum 6 pairs of MOFB or MOFOB photocells + 2 pairs of MOFB or
MOFOB photocells assigned as Opening devices + max. 4 MOMB or MOTB control devices
For normally closed, normally open or 8.2 kΩ constant resistance contacts in self-learning mode (a change from the
memorised state prompts the "STOP" command)
for normally open contacts (closure of the contact prompts the P.P. command)
for normally open contacts (closure of the contact prompts the OPEN command)
for normally open contacts (closure of the contact prompts the CLOSE command)
SM connector for SMXI, OXI and OX2 family receivers
52 Ω for RG58 or similar type cable
8 ON-OFF type functions and 8 adjustable functions
• Self-learning of devices connected to the BlueBus output
• Self-learning of type of device connected to "STOP" terminal (NO, NC or 8.2 kΩ resistance contact)
• Self-learning of leaf travel and automatic calculation of deceleration and partial opening points (vary according to
installation)
- 20 °C ÷ 50 °C
NO
IP 54
310 x 232 x H 122
4,1

Publicidad

Tabla de contenido
loading