01. Press and hold down the key "Set" (for approx. 3 seconds).
02. Release the key when L1 LED starts flashing;
03. Press keys " " or " " to move from the flashing LED to the LED associated with the function to be modified;
04. Press "Set" to change the status of the function:
(short flash = OFF; long flash = ON)
05. Wait 10 seconds (maximum time) to exit the programming mode.
Note – During this procedure, points 03 and 04 need to be repeated when programming other functions to "ON" or "OFF" during the phase itself.
5.2 - Level two programming (adjustable parameters)
All level 2 functions are set by default as highlighted in grey in Table 8, and may
be modified at any time as explained in Table 7.
The parameters can be set on a scale from 1 to 8. To check the value corre-
sponding to each LED see Table 8.
01. Press and hold down the key "Set" (for approx. 3 seconds);
02. Release the key when LED L1 starts flashing;
03. Press keys
" or " " to move from the flashing LED to the LED associated with the "input LED";
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx. 3 seconds, until illumination of the LED representing the current level of the parameter to be modified;
06. Press keys " " or " " to move the LED representing the value of the parameter;
07. Release the "Set" key;
08. Wait 10 seconds (maximum time) to exit the programming mode.
Note – During this procedure, points 03 to 07 need to be repeated when programming other parameters during the phase itself.
Input
Parameter
Led
LED
(level)
L1
Pause time
L1
L2
L3
L4
L5
L6
L7
L8
L2
Step by
L1
step fun-
L2
ction
L3
L4
L5
L6
L7
L8
L3
Motor
L1
speed
L2
L3
L4
L5
L6
L7
L8
4 – English
TABLE 6 - Programming procedure (level one functions)
TABLE 7 - Programming procedure (level two functions)
TABLE 8 - Functions (second level)
Value
5 seconds
15 seconds
30 seconds
45 seconds
60 seconds
80 seconds
120 seconds
180 seconds
Open – Stop – Close – Stop
Open – Stop – Close - Open
Open – Close – Open- Close
Apartment block
Apartment block 2 (more than 2" generates stop)
Step-by-step 2 (less than 2" generates partial open)
Hold-to-run
Opening in semi-automatic mode, closing in hold-to-run mode
Very slow
Slow
Medium
Fast
Very fast
Extremely fast
Fast opening, Slow Closing
Extremely fast Opening, Medium Closing
IMPORTANT – In the programming procedure, the maximum time interval that
can elapse between activation of one key and the next is 10 seconds. When
this time elapses, the procedure terminates automatically, memorising the
modifications made up until then.
SET
3 s
SET
L1
o
SET
10 s
SET
3 s
L1
SET
o
SET
o
SET
10 s
Description
Sets the pause time, namely the time
which lapses before automatic clo-
sure.
This will only take effect if closing is
active.
Sets the sequence of controls asso-
ciated with the Step-by-Step input or
the radio control.
Sets the motor speed during normal
travel.