2.SC-510 panel setting

Setting of SC-510 (setting procedure of SS10)
Change the function setting mode below so as to operate the short stitch device.
(Note) For SC-510, there is a case where the setting of the thread trimmer of MF is changed by the control box. In
this case, refer to the setting of the thread trimmer of UT-25.
* For the basic operating procedure of SC-510 panel, refer to the Instruction Manual for SC-510.
(1) Changing the function setting mode (selection of SS10 devic)
2
3
3
Changing procedure (change of the service mode)
1
Setting of SS10
1
1
1
When the power is turned ON again, thread trimmer device and
SS10 device are set, and the devices can be used.
– 27 –
1) Pressing (+) switch 1, turn ON the power.
2) Continue to successively press switch 1 for three seconds
even when the screen display is displayed.
3) When the buzzer sounds two times, the service mode
starts up.
4) Press (▲) switch 2 to scroll 96 to 65.
5) Press (+) switch 1 and select the additional device
function.
6) When (+) switch 1 is pressed three times, [FUn] and
[UT1] are displayed, and [UT1] (function setting of
additional device 1) is selected.
7) When (▼) switch 3 is pressed once, operation is
determined and [U1.0] and [noP] are displayed.
8) When (+) switch 1 is pressed three times, [U1.0] and
[SS10] are displayed, and MF short stitch device is
selected.
9) Press (▼) switch 3 once to determine the selection of
the device.
After the determination, turn OFF the power switch.