(06), Sensor Reset (14) and Quick Exit
(16). You can change the function of
each key on every keypad. Please see
your system's Installation Manual for in-
structions on programming the keys, and
a complete list of all the function key op-
tions available for your system.
Clock Options
The LCD5501Z will display the current
time after 35 seconds of no key presses.
To set the correct time and date for the
system, please refer to your system's In-
struction Manual. You can change how
the keypad displays the time with the fol-
lowing options. To change the clock op-
tions:
1.
Enter [*][8][Installer's code]
2.
Enter [000] to go to keypad program-
ming
3.
Enter section [6] to go to clock op-
tions.
4.
To turn any of the options on or off,
press [1], [2], or [3]:
NOTE: If the Time does not display on keypad
option is selected, make sure that the Keypad
displays time when zones are open option is
also selected.
[1]ON =Time displays on keypad
OFF =Time does not display on keypad
[2]ON = Clock display is in AM/PM for-
mat
(e.g. 08:00 AM)
OFF =Clock display is in 24-hour format
(e.g. 20:00)
[3]ON =Keypad does not display time
when zones are open
OFF =Keypad displays time when zones
are open
5.
When you are finished programming
the clock options, press [#] to exit.
Alarms Displayed While Armed Option
You can disable the display of alarms on
the keypad when the system is armed.
The display of alarms is enabled by de-
fault. To disable the display of alarms
when the system is armed, turn off sec-
tion [6], option [5]:
1.
Enter [*][8][Installer's code]
2.
Enter [000] to go to keypad program-
ming
3.
To turn the display of alarms on or off,
enter section [6].
4.
Turn option [5] on or off:
[5]ON = Alarms not displayed while sys-
tem is armed
OFF = Alarms are always displayed
while system is armed
5.
When you are finished, press [#] to exit.
Emergency Key Options (Fire, Auxiliary,
Panic)
You can enable or disable the Fire, Aux-
iliary and Panic keys at each keypad.
These keys are enabled by default.
Please see your system's Installation
Manual for more information on these
keys and their options. To turn any of the
emergency keys on or off on the keypad:
1.
Enter [*][8][Installer's code]
2.
Enter [000] to go to keypad program-
ming
3.
Enter section [7].
4.
To turn the emergency key options on
or off, press [1], [2], or [3]:
[1]ON = Fire key enabled
OFF = Fire key disabled
[2]ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3]ON = Panic key enabled
OFF = Panic key disabled
5.
When you are finished, press [#] to ex-
it.
Door Chime Options
You can program the LCD5501Z keypad
to sound a tone when any zone is opened
or closed. There are two parts to the
LCD5501Z door chime programming:
• Program if the LCD5501Z will chime
when zones are opened and/or
closed.
• Program the type of sound the
LCD5501Z will make when an individ-
ual zone is opened or closed.
For the door chime feature to work, you
will also need to turn on the Door Chime
attribute for each zone that will trigger the
chime. This programming is done in the
control panel software. Refer to your con-
trol panel's Installation Manual for more
information.
Door Chime on Zone Openings/Closings
You can program each LCD5501Z key-
pad to sound a door chime when zones
3