Descargar Imprimir esta página

Migatronic FOCUS TIG 161 DC PFC Guía Rápida página 4

Ocultar thumbs Ver también para FOCUS TIG 161 DC PFC:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
11
12
4
5
2
10
13
16
14
15
9
7
1. Welding current/Arc voltage
Press the key and turn the control knob to set the
welding current.
Keep the key pressed for 3 seconds to display the arc
voltage. Repress the key to display the welding current.
2. Welding voltage
The LED is lit, when there is voltage on MMA electrode
or TIG torch.
3. Parameter units
Units of measurement of the selected parameter.
4. Overheating
The LED is lit, when the machine is stopped due to
overheating.
5. Mains error
The LED is lit, when the mains voltage is too high or
too low.
3
6. Welding process
Selection of MMA/TIG welding process.
1
7. Trigger mode
Selection of 2-stroke/4-stroke.
8. Current adjustment
Selection of torch adjustment.
9. Ignition method
8
6
Selection of HF/ LIFTIG
10. Gas pre flow
The time for which gas flows until the arc is established.
11. Slope up
The time from start amp to welding current.
12. Slope down
The time from welding current to stop amp.
13. Gas post flow
The time for which gas flows after the arc is
extinguished.
14. Pulse
Key activated = pulse.
®
ignition.
QUICKGUIDE
FOCUS TIG 161 DC PFC
15. Pulse setting
Press the menu key until the requested LED is lit:
• Pulse time: Welding current period
• Pause time: Base current period
• Base amp: % of pulse current
16. Selection of secondary parameters
Opens parameters 10, 11, 12, 13 and 14.

Publicidad