10
STERILIZERUV PS
OPERATING MANUAL
INTRODUCTION, PURPOSE
Dear Customer, we congratulate you on your excellent choice of high quality ultraviolet
sterilizer, intender for water sterilization in water gardens, garden ponds and fish ponds.
Prior to installation of the device please read these instructions carefully. Persons unfamil-
iar with these operating instructions should NOT operate this device.
PARTS LIST /see fig. 1/
No.
Part name
1
Complete housing
2
Mounting bracket
3
Complete fitting, including:
3a
Complete stabilizer
3b
Frame
3c
Starter socket
3d
Fluorescent lamp fitting
4
Screw cup
5
Screws 3,1x10
6
Stopper
7
Gasket 26x3,5
8
Starter
9a
Head
9b
Quartz tube
10
Gasket 26x3,5
11
Gasket 53x3
12
UV fluorescent tube
13
Connecting stub
14
Setting bush with thread
15
Quart tube gasket 38x3
16
Distance sleeve
PS – 15 W
PS – 30 W
PS – 55 W
101765
101766
101766
101766
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3,1x10
3,1x10
3,1x10
-
-
-
26x3,5
26x3,5
26x3,5
-
-
-
-
-
-
-
-
-
26x3,5
26x3,5
26x3,5
53x3
53x3
53x3
200389
200097
200232
100241
100241
100241
-
-
-
38x3
38x3
38x3
-
-
-

TECHNICAL SPECIFICATION

Voltage: 230 V
Frequency: 50 Hz
Types
T8 (T26) UV-C
Fluorescent tube length – without
connectors [mm]
Power consumption [W]
Max. pressure [bar]
Max. pond volume [m
3
]
Max. pump output [l/h]
Recommended AQUAEL pump
Max. submersion depth [m]
Net mass [kg]
Degrees of protection of enclosure: IP X8
LIST OF FIGURES
1. Sterilizer parts
2. Removal of fitting from the housing
3. Placing the fitting in the housing
4. Cleaning of the gasket
5. Removal of fitting from the cover
6. Replacement of fluorescent tube and starter
7. Cleaning of the housing gasket (7)
8. Quartz tube replacement

DEVICE SPECIFICATIONS

Water pumped through the device flows in a thin layer directly within the range of UV-C
ultraviolet radiation, which destroys algae, bacteria and other pathogenic organisms. Ow-
ing to the operation of the sterilizer, water always remains clean in the biological sense,
and fish and plants live in a comfortable and healthy environment – you can forget green
water with algae forever.
Important features, distinguishing the STERILIZERUV:
total submersibility – possibility of application both inside and outside of water tank;
thermal switch (installed in the stabilizer) –in abnormal operating conditions (e.g. when
the stabilizer is covered or the starter is damaged) it shut off power supply to the sterilizer
until it cools down. Restart will take place automatically;
10-meter power supply cord enabling comfortable location of the device;
metal housing ensuring high durability of the device;
universal connectors – enable adaptation of device inlet and outlet diameter do the
plumbing diameter applied in water circulation in the given case.
SAFE OPERATION CONDITIONS
✔ Prior to commencement of installation of the ultraviolet sterilizer please read these
operating instructions carefully. Keep the sterilizer out of reach of children. Make
sure persons unfamiliar with these instructions have no access to the device.
✔ Prior to commencement of installation or maintenance activity on the sterilizer,
make sure it (and the collaborating pump) is disconnected from the mains by pull-
ing the plugs from the sockets.
✔ Prior to commencement of any installation of the sterilizer make sure, by removing
the housing as described in the chapter „Cleaning...", figure 2 and 3, that the internal
glass elements (quartz pipe and UV fluorescent lamp) are not cracked or broken. If
11
ENGLISH
PS – 15 W
PS – 30 W
PS – 55 W
15 W
30 W
55 W
437
893
893
22
36
68
0,5
0,5
0,5
15
30
50
3500
7000
9000
PFN 3500
PFN 7500
PFN 10000
1,5
1,5
1,5
2,72
3,00
3,10