Technical Data - Lenze E94AYAE-SM301 Instrucciones Para El Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2

Technical data

2
Technical data
24 V supply
The module and the safe output must be supplied with 24 V from safely separated power
supply units. To maintain electrical isolations, separate voltage supplies are required.
Detailed features of the 24−V supply
Terminal
Specification
+, −
Supply voltage of the module via a safely
separated power supply unit (SELV/PELV)
Input current
24O, GO
Supply voltage of the safe output via a safely
separated power supply unit (SELV/PELV)
Input current
Safety functions
,
The manual for the safety module contains information on the safety
functions.
28
l
[Unit]
min.
typ.
[V]
19.2
24
[mA]
[V]
18
24
[mA]
EDK94AYAE DE/EN/FR/ES/IT 3.1
max.
30
350
30
1100

Publicidad

Tabla de contenido
loading

Tabla de contenido