Advanced Settings - Allmatic HELIOS KAIROS Manual De Instrucciones

Ocultar thumbs Ver también para HELIOS KAIROS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7
CLIMATIC SENSOR
7.1 Learning a clima• c sensor
1. Press and release the learning key on the control unit, the red LED lights up.
2. Press and release the key on the sensor, the control unit signals the correct memoriza! on with two fl ashes
of the red LED.
Once memorized the sensor, you can test the transmission by pressing the key on the sensor. The control unit
shows the recep! on of the broadcast with a rapid fl ashing of the yellow LED.
7.2 Checking the motor direc• on during in alarm
This procedure is necessary to verify correct wiring of the motor, so that the awning will be closed in case of
alarm.
1. Temporarily disable the opera! on of the light sensor DIP 5 OFF.
2. With a transmi$ er or cabled inputs move the awning at about halfway and stop it.
3. On the KAIROS sensor, adjust the trimmer to minimum wind (TEST) and rotate the blades of the sensor at
a constant speed for few seconds. On the used AXEM sensor,shake the awning un! l the interven! on of the
sensor.
4. The control unit will show the alarm with the blinking of the red LED and will reclose the awining.
If the awning moves in opening remove power to the control unit and swap the motor cables 14-15 and make
again the test above. If the awning moves in closing, wait un! l it is completely closed, press and hold the
learning key un! l the red LED start blinking faster, release the bu$ on.
Set the desired speed of wind on the sensor with the trimmer and re-able the light sensors DIP 5 ON.
7.3 Dele• ng a clima• c sensor
1. Press and release the learning key on the card, the red LED lights up.
2. Press and release the key on the sensor, the control unit shows the dele! on with four long fl ashes of the
red LED.
7.4 Behaviour of the AXEM sensor
The alarms of the AXEM sensor are disabled for all the working ! me of the control unit and for more:
• 10 seconds, for the wind alarms;
• 15 minutes, for the ! lt alarms.
To delete the wai! ng ! me and enable the sensor immidiately, press the learning bu$ on on the Axem device.
8

ADVANCED SETTINGS

8.1 Se• ng the par• al open posi• on (only with light sensor enabled)
You can set a desired posi! on for automa! c opening due to the light sensor, this procedure can only be done
if the light sensor is present and enabled (DIP 5 ON):
1. Close the awning.
2. Upon reaching the closed posi! on, press and hold the learning key on the control unit un! l the red LED
fl ashes rapidly, release the key.
3. Press and hold the open key of a transmi$ er or (only with DIP 2 ON) a cabled input un! l the yellow LED
fl ashes quickly, the awning begins to open, release the bu$ on.
4. To set the posi! on it's suffi cient to stop the awning (with a stop or a close input).
18/44
ITA
ENG
FRA
ESP
DEU
POR
6-1621090
rev3
16/03/2016

Publicidad

Tabla de contenido
loading

Tabla de contenido