Assembly with Vinyl and Web Belt
1. Place the belt through the plastic belt holder on the PAPR motor blower.
2. If using the CB-1000 Comfort Belt refer to separate User Instructions for information on assembly.
3. Thread the belt into the belt slot on the back of the GVP-111 battery. (Placing the GVP-111 battery onto the belt last will allow for easier removal
for charging.)
4. The BP-15 battery is equipped with a clip that slides on and off the belt. Ensure that the bottom of the BP-15 battery clip is underneath the belt.
5. Connect the power cord to the battery and the PAPR unit as demonstrated in Figs 1 and 2.
6. Secure the belt to your waist and adjust for a snug fit. Feed any excess belt length through the belt loop or cut to the desired length.
Note:
The PAPR and GVP-111 battery are designed so they may be positioned on the left, right or center of the back.

BP-15 Battery Charging

Refer to BC-210/BP-15 User's Instructions.
The BP-15 battery should be charged immediately upon receipt and stored on the BC-210 charger between uses. If the BP-15 will be stored off
the charger, it should be fully charged initially and then fully recharged once every three months if not used sooner.

GVP-111 Battery Charging

Refer to GVP-111 User's Instructions.
NOTE: The GVP-111 should be charged for a minimum of 20 hours before initial use.
Users should also refer to 3M Technical Data Bulletin #178 – Maintenance and Care of 3M™ Powered Air Purifying Respirator (PAPR) Batteries
(www.3M.com/OccSafety).

Filter/Cartridge Assembly

Be certain that the filter and/or cartridge that you are placing on the unit is appropriate for the contaminants to which you will be exposed.
Failure to do so may result in sickness or death.
Do not over-tighten filter/cartridge. Over-tightening may result in distortion or displacement of the seal and may allow contaminated air to enter
the respirator headpiece and may result in sickness or death.
1. Remove the plastic caps from the cartridge/filter.
2. Inspect the cartridge/filter for damage to the threads, plastic body or filter media. Discard if damaged.
3. Remove inlet and outlet motor/blower plugs as shown and check that the gaskets are in place. Do not discard the
plugs; they should be re-inserted during cleaning (Fig. 3).
4. Inspect the gaskets in the inlet and outlet ports for cracks or excessive wear. If needed, replace with inlet gasket or
outlet gasket (GVP-101 contains both gaskets).
5. Secure the cartridge/filter into the inlet of the motor/blower unit by hand tightening.
6. Connect the power cord between the battery and motor/blower unit (Fig. 1 and 2).
Fig. 3

Connecting Breathing Tube to GVP-100 Motor Blower

1. If using the H-115, GVP-122, L-122 or GVP-123 breathing tube, screw the threaded end into the outlet port of the GVP-100 as shown in Fig. 4.
2. If using a BT series breathing tube, first screw the 3M™ V-199 adapter into the outlet port of the GVP-100. Then attach the BT breathing tube
to the adapter by inserting the tube end with two prongs into the top of the adapter. Twist the end of the tube to lock it in place (Fig.5).
Fig. 4

Connecting the Breathing Tube to the Headgear (Respiratory Inlet Cover)

Follow the instructions below for the headgear to be used and refer to the specific headgear User Instructions for additional information.
3M™ Full Facepiece Respirators 7000 Series
Fig. 6
Fig. 5
1. Remove the 3M™ 7890 Center Port Plug from the full face respirator. Ensure 7890 plugs are in place on each
side port of the respirator (Fig.6).
2. Screw GVP-123 breathing tube elbow adapter into the center port of the 7800S facepiece inlet of the respirator
(Fig. 6).
3. Follow user donning and seal check procedures described in the User Instruction provided with the 7800S
facepiece.
4. Screw the breathing tube inlet into the 3M™ PAPR outlet. Activate the unit with the power switch on the
battery pack.
WARNING