11 Disassembly
Fault
Powder is introduced
unilaterally
11 Disassembly
EN - 22
Cause
• Powder nozzle bore partly
clogged
• Powder gas volumetric flow too
strong or too weak
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the entire welding system.
NOTICE
• Disassembly may only be carried out by qualified personnel (in
Germany see TRBS 1203).
• Please consult the operating instructions for the welding components,
such as the welding power source and the robot control.
• Observe the information provided in the following section:
8 Putting out of operation on page EN-18.
1 Disconnect the cable assembly from the power source and powder delivery
unit.
2 Remove the parts to be disconnected.
®
ABIPLAS
WELD 100/150 POWDER W
Troubleshooting
• Clean powder nozzle and
replace it if necessary
• Adjust powder gas volumetric
flow setting