ABIPLAS
WELD 100/150 POWDER W
9.1 Torch neck
NOTICE
• The specified maintenance intervals are standard values and refer to
single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Check the coolant hose, seals and connectors for damage or leaks and
replace if necessary.
• Always wear your personal protective equipment when performing
maintenance and cleaning work.
1 Remove the gas nozzle.
2 Remove any welding spatter and powder residues.
NOTICE
• Do not use anti-adhesives. Anti-adhesives clog the powder channels.
• Replace the centering ceramics as soon as deposits become visible on
the surface. Deposits may result in high-voltage flashovers that destroy the
torch body.
3 Check the wear parts for visible damage and replace them if necessary.
4 Unscrew the back cap and remove the tungsten electrode.
5 Sharpen the tungsten electrode as follows:
Sharpening the tungsten electrode depends on wear and must therefore be
carried out when required.
Fig. 5
Sharpening the tungsten electrode
9 Maintenance and cleaning