English
1
User instructions
Valve terminal type VTSA-ASI-...-4E4A-Z has been designed
exclusively for controlling pneumatic actuators and is only
suitable for use in bus systems in accordance with the
AS-Interface specifications. If additional commercially-
available components are connected, the specified limits
for pressures, temperatures, electrical data, torques, etc.
must not be exceeded.
The valve terminal enables the control of 4 valve solenoid
coils and the registering of 4 sensors. The exchangeable
connections of the CPX system are used for connecting the
sensors.
AS-Interface bus systems and valve terminals may only be
installed by personnel especially trained for this purpose.
Specifications on the design and addressing of your bus sys-
tem can be found in the manual for the AS-Interface master.
Detailed information on the pneumatic components of the
valve terminal can be found in the Pneumatics manual type
P.BE-VTSA-... .
Caution
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Commission only a valve terminal which has been
fitted and wired completely.
S Connect the earthing cable between the adapter
module and the multipin node.
S Switch on the power supply only if the DIL switch is
positioned at a permitted setting.
Festo VTSA-ASI-...-4E4A-Z 1108a English
17