3.5 Address assignment of the solenoid coils
Depending on the linking up to 4 valve locations can be
assigned. The following applies to VABV...T2:
–
solenoid coil 14 occupies the lower-value address,
–
solenoid coil 12 occupies the higher-value address.
Addresses are assigned on the solenoid coils in ascending
order without gaps, from left to right.
The number of assigned addresses per valve location
depends on the manifold base, irrespective of whether
valves or cover plates are fitted.
Examples of combinations of electric VABV linkings
(not all possible combinations are shown)
VABV...-2T1: 2 locat. per 1 coil
VABV...-T1: 1 location, 1 coil
VABV...-2T2: 2 locations per 2 coils
VABV...-T2: 1 location, 2 coils
VABV...-T1... | -2T1... | -T1
VABV...-T2... | -T1 ... | -T1
Symbol:
1)
T1: black dot on type plate and red coil contact
2)
T2: black dot on type plate and red coil contact
*)
For single-solenoid 5/2-way valves
24
0
Valve locations/solenoid coil
1) *)
V1/14 V2/14 V3/14 V4/14
1) *)
V1/14 V2/14 V3/14 V4/14
2)
V1/14 V1/12 V2/14 V2/12
2)
V1/14 V1/12 V2/14 V2/12
V1/14 V2/14 V3/14 V4/14
V1/14 V1/12 V2/14 V3/14
Festo VTSA-ASI-...-4E4A-Z 1108a English
Addresses
1
2
3