Collar Tab
Transfer
Tube Stop
Collar Tab
Transfer tube
hole must
Remove and
line up with
discard grey
large port.
3-way stop
collar.
3. Convert to Two-Way Valve
CAUTION: Risk of property damage. For a two-way
configuration only: the auxiliary outlet must be capped off to
prevent possible leakage out of the unused auxiliary outlet,
and the grey collar must be changed to the black two-way
stop collar.
NOTE: The valve is pre-assembled for use as a three-way transfer
valve.
Remove the plated nut.
Carefully pull the cartridge from the brass body.
NOTE: Use care to prevent the cartridge seals and O-rings from
falling off, or becoming dirty or damaged.
Line up the transfer tube stop with the slot in the grey collar.
Use a flat-blade screwdriver to carefully pry the two locking tabs
loose from the transfer tube.
Remove and discard the grey three-way stop collar.
Verify the hole in the transfer tube lines up with the large port in
the cartridge.
Align the black collar on the transfer tube with the collar tab lines
on the large port of the cartridge.
Snap the collar in place to ensure both locking tabs are fully
engaged.
086847-2-AC
Black 2-way Collar
Grey Collar Slot
Locking Tab
Notch
Auxiliary
Outlet
Cap
6
Plated Nut
Cartridge
Inspect seals
and o-rings.
Brass Body
Kohler Co.