Install the Transfer Valve (cont.)
Remove the plaster guard and plated nut from the valve. Do not
remove the cartridge.
Remove the collar from the brass body.
Thread the mounting nut down onto the brass body.
Slide the washer onto the brass body until it is flush against the
mounting nut.
Slide the valve up through the deck/rim and thread the collar
part way onto the brass body with the flange up.
Hand tighten the plated nut onto the brass body.
Reinstall the plaster guard.
Position the collar to create a gap 1/8" (3 mm) to 9/16" (1.4 cm)
between the finished deck and the bottom of the plaster guard.
Securely tighten the mounting nut until it is flush against the
finished deck.
Dry fit all the piping and connectors.
Solder the remaining piping and connectors.
5. Install the Handshower
Install the hose guide and handshower according to the
instructions packed with the product.