RS01
8 - Programmable functions:
The table shows the functions that can be activated via the dip switches, the control unit reads the dip switches with the gate stationary on closing:
Status of dip
Dip switch number
switch
DIP 1-1
OFF
DIP 1-1
ON
DIP 1-2
OFF
DIP 1-2
ON
DIP 1-3
OFF
DIP 1-3
ON
DIP 1-4
OFF
DIP 1-4
ON
DIP 1-5
OFF
DIP 1-5
ON
DIP 1-6
OFF
DIP 1-6
ON
DIP 1-7
OFF
DIP 1-7
ON
DIP 1-8
OFF
DIP 1-8
ON
DIP 2-1
OFF
DIP 2-1
ON
DIP 2-2
OFF
DIP 2-2
ON
22
Automatic closing function off
Automatic closing function on
Condominium function on (during gate opening it is not possible to stop the movement with the remote control
or AP/CH inputs)
With each command the gate: opens, stops, closes, stops
Pre-flashing off
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
STPA input as internal photocell
STPA input as sensitive edge
Photo-test function off
Photo-test function on (photocell checking with each command) see paragraph 4.6.3
Second radio channel associated with pedestrian gate opening
Second radio channel associated with activation for 1 second of 2can output (terminal 3 and 4)
Sensitive edge with normally closed contact
Resistive sensitive edge, normally open contact with balancing resistance of 8.2 K Ohm in parallel
Close immediately function off
Enables the close immediately function (the photocell tripping takes the automatic closing time to 5 seconds,
from its disengagement)
Limit switch inputs used
Limit switch inputs not used
For opening the gate to the left
For opening the gate to the right
Description
EN