General 706 Series Instructions; 706 Series Controller - Aquanex AQU36 Manual Del Propietário

Ocultar thumbs Ver también para AQU36:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GENERAL 706 SERIES INSTRUCTIONS

706 SERIES CONTROLLER

Power Loss Memory Retention
The 706 Series controllers feature battery-free
time and date retention during the loss of power.
This is designed to last a minimum of 8 hours
depending on the installation. The controller
will continue to keep time and day in dynamic
memory while there is no AC power.
The controller will not track water usage in the
event of a power failure.
Information entered or calculated by the
controller is stored in two different ways.
1.
A static memory will store:
User programmed values
Salt setting (salt setting)
Hardness setting
Daily averages (history values)
These parameters will not be lost in the
event of a power failure
2.
A dynamic memory with 8 hour retention
will store:
Time of day
Todays water used
Power interruptions longer than 8 hours may
cause the controller to lose the time setting.
When power is restored, the time setting must
then be re-entered.
27 • 1/12
Motor
The 706 series controller uses a standard
12-volt AC motor.
Power
706 Series controller is available in one power
configuration:
The North American model requires 60 Hz input.
Variable Reserve Function
The 706 Series metered-demand volumetric
controller is designed to have a variable reserve
feature. This feature automatically adjusts the
reserve to the end-user's water usage schedule.
A variable reserve saves salt and water by only
regenerating when absolutely necessary, and
ensures enough soft water for typical high-water
usage days.
Each day the controller reviews the last four
weeks of water usage for the same day of the
week to determine if the remaining capacity is
adequate for the next day of the week. If the
remaining capacity is not adequate, it will initiate
an automatic recharge.
NOTE: Water flow to the valve can be turned on
or bypassed when the controller is powered up
for the first time.