PERFORMANCE DATA SHEET

AMERIFLOW 20-1200-AQU36 WATER SOFTENER SYSTEM PERFORMANCE DATA SHEET
Model
Rated Service Flow (gpm)
Pressure Drop at Rated Service
Flow Rate (psid)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
Indion 225 NaF
Ion Exchange Resin (cu ft)
Tank size
Backwash - GPM
Rapid Rinse/purge - GPM
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter², Operating Temperature: 35 - 100° F or 1.7 – 38° C
Acceptable Salt Type: Sodium Chloride – Pellet salt
All Systems above tested at 35 psi ± 5 psi, pH of 7.5 ± 0.5, Capacity Testing Flow Rate = 50% of the rated
service flow rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI
44 for specific performance claims as verified and substantiated by test data. The
rated salt efficiencies above were also determined in accordance with NSF/ANSI 44
and are only valid at the salt dosage referenced above. An efficiency rated water
softener is a demand initiated regeneration (DIR) softener which also complies with
specific performance specifications intended to minimize the amount of regenerant
brine and water used in its operation. Efficiency rated water softeners shall have
a rated salt efficiency of not less that 3350 grains of total hardness exchanged per
pound of salt (based on NaCl equivalency) (477 grams of total hardness exchanged
per kilogram of salt), and shall not deliver more salt than its listed rating. The rated
efficiency of the water softener, the salt dosage at that efficiency, the capacity at that
salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency
is measured by a laboratory test described in NSF/ANSI 44. The test represents
the maximum possible efficiency the system can achieve. Operational efficiency is
the actual efficiency achieved after the system has been installed. It is typically less
than the efficiency due to individual application factors including water hardness,
water usage, and other contaminants that reduce the water softener's capacity.
These systems are not intended to be used for treating water that is microbiologically
unsafe or of unknown quality without adequate disinfection before or after the system.
Refer to the system Installation and Service Manuals for set-up and programming
instructions.Contact your local Ameriflow dealer for parts and service. See your
owners manual for warranty information.Important Notice: For conditions of use,
health claims certified by the California Department of Public Health and replacement
parts, see product data sheet.
Iowa Requirement:
Seller: ___________________________________________ Date: ______________
Buyer: ___________________________________________ Date: ______________
9/28/11
59 • 1/12
20-1200-AQU36
11.0
15.0
15,821 @ 3.6
29,481 @ 11.3
36,089 @ 17.5
4,400 lbs salt @ 3.6 lbs
2.7
1.09
10" x 35"
2.7
2.7
Ameriflow Water Systems Inc.
525 W. 21st Street
Tempe, Arizona 85282
PH (602) 275-4188
Tested and
Certified by WQA
against NSF/
ANSI Standard
44 for softener
performance & 372
for "Lead Free"
compliance.