AQU36 706 CONTROL TROUBLESHOOTING GUIDE

The AQU36 continuously monitors itself and
sounds an alarm if it detects something wrong.
The alarm is a beep that is on for one second
and then off for nine seconds. When the alarm
sounds, the display shows the letters "Err" with
a number 1 or 3. The table below lists the Err
706 Control - Error Codes
Problem
Err 1 is
Program settings have been corrupted.
displayed.
Err 3 is
Control does not detect the camshaft
displayed.
position and is returning to the service
position.
Camshaft is not turning during Err 3
display.
Camshaft is turning more than five
minutes to find Home position:
57 • 1/12
Possible Cause
numbers, a description of each error, the cause
of the error, and the solutions. To silence the
alarm, press any button on the control. If the
error still exists, the control will go back to the
alarm condition after 30 seconds.
Press any key. If Err 1 does not clear,
replace control.
Wait until the control returns to the
service position. Flashing hourglass in the
display indicates that the motor is running
Check that motor is connected. Verify that
the motor wire harness is connected to
motor and controller module. Verify that
optical sensor is connected and in place.
Verify that motor gear has engaged the
camshaft.
If everything is connected, replace
components in this order:
1. Motor Assembly, Optical Sensor
2. Control
Verify that optical sensor is in place and
connected to wire. Inspect for debris in
the camshaft slots.
If motor continues to rotate indefinitely,
replace the following components in this
order:
1. Optical Sensor
2. Control
Solution