Module Ts4; Bircher Isat-Bottom Safety Edge Device - Teckentrup TS4 Instrucciones De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
TS4-4 module
Jumper X6 PIN 1 and 2
45 sec.
60 sec.
30 sec.
90 sec.
20 sec.
120 sec.
10 sec.
5 sec.
240 sec.
no automatic timer
Page 12

Module TS4-4

For connection of radio, Fraba-OSE-BOTTOM SAFETY EDGE DEVICE,
Bircher ISAT-BOTTOM SAFETY EDGE DEVICE, with time-controlled re-closing
Take out TS basic module.
• Remove TS base module from terminal block X8.
• Insert module TS4-4 in terminal block X8 (observe coding
slit).
• Plug jumper X6 upon PIN 1 and 2.
LED green: Ready for operation
LED red:
Flashes if block is operated / ON after test fault
LED yellow: Flashes if learning / ON in case of radio receipt or
reception of impulse
terminals:
Function
1
+24V
2
+12V
3
SIGNAL
4
0V (GND)
Jumper J1:
Inserted
=> reversion is switched on
Open
=> reversion is in general OFF
Jumper J2:
Inserted
=> Blocks not tested in final position
Open
=> blocks tested in final position
(switching block must give an impulse before
limit switch-down)
Setting of automatic re-closing:
• Set rotary switch S1 to desired time
(see accompanying illustration).
Insert TS4-4 in terminal block X8
(coding slit in accordance with mark
on circuit board).
Fraba OSE
Bircher ISAT
not used
cable 1
cable brown
not used
cable green
cable 3
cable white
cable 2

Publicidad

Tabla de contenido
loading

Productos relacionados para Teckentrup TS4

Tabla de contenido