Sectional door
6
5
4
3
2
1
Button TA2
Button TA1
Circuit board TS4
vario (cutout)
control cam 1
(green)
Operator for
additional
rolling shutter
switch
OPEN
Operator for
additional
sectional door
switch
OPEN
Page 8
Setting of limit switch (operator)
A
B
End of travel position door CLOSE
• Travel door to the desired CLOSE position operating button
TA2 (white).
• Adjust control cam 5, so that limit switch is operated.
Screw Allen screw A 2.5 mm tight.
• Make fine adjustment with Allen screw B.
End of travel position door OPEN
• Travel door to the desired OPEN position operating button TA1
(green)
• Adjust control cam 2, so that limit switch is operated.
Screw Allen screw A 2.5 mm tight.
• Make fine adjustment with Allen screw B.
• The emergency limit switches 3 and 4 have to be adjusted so that they
are activated immediately on passing of the control limit switches.
• Check securing screws A after test run.
The additional limit switches 1 and 6 have potential-free
change-over contacts.
control cam 2
control cam 3
(green)
(red)
limit switch
safety
limit switch
OPEN
OPEN
limit switch
safety
limit switch
OPEN
OPEN
Rolling shutter
1
2
3
4
A
B
control cam 4
control cam 5
(red)
(white)
safety
limit switch
limit switch
CLOSED
CLOSED
safety
limit switch
limit switch
CLOSED
CLOSED
5
6
control cam 6
(white)
additional switch
CLOSED
additional switch
CLOSED