MODEL ICBUW-24 / ICBUW-24FS SITE PREPARATION
Opening Dimensions
MODEL ICBUW-24
610 mm
OPENING
DEPTH
TOP VIEW
876 mm
W
OPENING
OPENING WIDTH
HEIGHT
SIDE VIEW
FRONT VIEW
OPENING WIDTH
ICBUW-24
610 mm
Two 610 mm Models*
1222 mm
*A dual installation kit will be required for this installation.
DUAL INSTALLATION
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 51 mm filler strip is recommended between
units. Dual installations without a filler strip can only be
accomplished using two units with opposite hinges. Refer to
the illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer.
WITHOUT FILLER STRIP
FILLER STRIP
W
Opposite hinges.
Same side hinges.
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
ELECTRICAL REQUIREMENTS
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
Receptacle
grounding-type (earthed)
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded (earthed).
LEFT SIDE
OF OPENING
51
394 mm
mm
76 mm
E
FLOOR
Electrical supply location.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Preparation
To operate properly, the door must open a minimum of 90°.
Use a minimum 76 mm filler in corner installations to assure
a 90° door opening.
Uncrate the unit and inspect for damage. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket, hardware and the leveling legs which hold the
wood base to the bottom of the unit.
10 amp
subzero.com
| 3