PSo
The torque applied to the motor during braking in the closing phase is adjusted.*
PSC
The torque applied to the motor during braking in the opening phase is adjusted *
The trigger time of the anti-crash device (Encoder) is adjusted during the normal
SEAV
speed phase*.
99: maximum sensitivity – 0: Minimum sensitivity
The trigger time of the anti-crash device (Encoder) is adjusted during the braking
SEAR
phase*.
99: maximum sensitivity – 0: minimum sensitivity
Activated only with SERL:ON Logic. The activation time of the service light is ad-
TLS
justed.
The force of the motor brake is adjusted.
ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
IbL
transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
PP and PED controls are enabled or disable during the TCA phase.
IBCA
On: PP and PED control units are disabled.
Off: PP and PED control units are enabled.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell ac-
SCL
tivation causes the automatic closure of the gate after 3 s. It is activated only with
:ON
TCA
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
PRE
starting of the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
During the TCA phase, the PP and PED controls are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled. See section "Operating mode with enabled/
disabled Encoder"
ENC
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
An incorrect setting of these parameters may result in a danger.
Comply with regulations in force!
LOGICS (LOG)
FUNCTION
* WARNING:
1-99-(50%)
1-99-(50%)
0-99-(0%)
0-99-(0%)
1-240-(60s)
0-99-(50%)
MEMO
DEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
OFF
15