Connection And Operation - Genius LYNX 06 Advertencias Para El Instalador

Ocultar thumbs Ver también para LYNX 06:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48
5.. CN TERMINAL-BOARD
5.1.1. e
arthing
Terminal "1". Connect the yellow-green power cable to this terminal.
The connection is absolutely necessary for correct operation of the
control unit.
5.1.2. p
ower supply
Terminals "2 & 3". Connect, to these terminals, the two cables incoming from
the 230/115 Vac power supply line according to board model.
Connect the neutral wire to terminal 3 and the phase to terminal 2.
5.1.3. F
lashing laMp
Terminals "4 & 5". Output 230/115 Vac max. 25 W. The flashing lamp power
cable must be connected to these terminals. The flashing lamp is active
while the automated system is moving, whereas when the system is open
or closed, it stays OFF. Before the opening manoeuvre, the flashing lamp pre-flashes on steady beam for 0.5 sec. If the
assistance request function has been activated, an when the set number of cycles has been reached, at the end of
the closing manoeuvre, the flashing lamp continues to flash for another 5 seconds, indicating that the set cycles have
been reached. For the cycles resetting operation, see paragraph 10.1.
5.1.4. M
otor
Terminals "6, 7 & 8". Output 230/115 Vac max. 500 W. Connect the motor power cables to these terminals. For the cable
connection sequence, refer to the following table:
The colour of the wires connected to terminals 6 & 8 can be reversed according to motor rotation direction
4. BOARD LAYOUT

5. CONNECTION AND OPERATION

Terminal No.
Motor 230 Vac
6
Black
7
Blue / Grey
8
Brown
1
Yellow Green
Components
CN1
Power supply terminal-board
CN2
Encoder connector
CN3
Travel limit terminal-board
Terminal board for commands / powering acces-
CN4
sories
CN5
Capacitor connector
JP1
Connector for radio module
DSP1 Display
Fuse for transformer primary winding/Motor
F1
power supply
F2
Fuse for accessories/indicator light
P1
Parameters adjustment push-button
P2
Parameters adjustment push-button
OPEN/CLOSE radio channel memory storage
P3
push-button
CLOSE radio channel memory storage push-but-
P4
ton
P5
RESET push-button
FCA
FCA input LED
FCC
FCC input LED
CLOSE CLOSE input LED
OP/CL OPEN/CLOSE input LED
FSW
FSW input LED
STOP STOP input LED
DL7
OPEN/CLOSE radio channel LED
DL8
CLOSE radio channel LED
Motor 115 Vac
Black
White
Red
Green
8

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido