5.6. Replacing the filter
Only use original filter that is supplied by an
official distributor.
1. Press the central part of the fastening bar of filter 22
and pull the left end upwards to lift bar 22.
2. Press both fastening tabs inwards to free the fastening
frame and the filter.
3. Change the filter and place the frame in such a way
that it fits into hooks 21. Ensure the tabs hold the filter
before closing bar 22.
5.7. Replacing Batteries
The filter is powered by solar cells from the electric arc
formed. As a backup, the filter has two batteries which
ensure a fully reliable system.
Indicator 5 lights up when the batteries run out for these
to be replaced.
PROCEDURE
Extract the filter (section 7.6) and press outwards with the
tip of a flat-blade screwdriver to extract the class CR2450
batteries and replace with them with new batteries.
Warning: never replace just one of the
batteries. Always replace both batteries
5.8. Guarantee
Guarantee card
Included in the documentation that accompanies this
equipment, you should find the warranty card.
You should fill out the card completely and return to
vendor with a copy of purchasing receipt or invoice and
you should receive a receipt.
Note: If you cannot find the warranty card within the
documentation, you must ask for it through your
supplier.
Conditions of warranty
As with professional equipment, there is established a
warranty period of one year from the date of purchase.
The warranty will expire immediately if the Customer
Attention department in the Central Office does not
receive the warranty card within one month of the date of
purchase.
The warranty will also expire if this equipment is used in
an inappropriate manner or accessories are used that are
not appropriate to the specifications of the manufacturer.
The warranty is limited only to manufacturing defects and
expire if pieces have been removed or manipulated or
repaired other than the manufacturer.
ENGLISH
16
STAYER repair of defective parts or replacement is
granted only after being analyzed by its technicians.
All costs of shipping and disassembly will be considered
to part of the purchaser.
To make it easier for technicians, a list of defects that
where found during use should be supplied.
6. INSPECTION
Before each use, mandatorily inspect the equipment. Do
not use the equipment if it does not comply with any of the
following circumstances. Any component not valid should
be replaced immediately.
The harness to the head is clean, complete and adjusts
perfectly to the head.
The helmet is clean, complete and does not present any
type of crack.
The filters should be complete with no embedded
projection chips or cracks, including the protection lenses.
The filter must cover completely is slot in a way the no
type of light passes through.
The photo sensors must be visible under any circumstance
and not covered by any particles.
The filter should not be used if it has exceeded its
expiration date. Verify that 2 years have not passed
from the traceability code. Check the first four characters
(starting from the left) in the code marked on interior part
of the automatic darkening filter. First two are the year and
second ones are the week.
Make sure that the automatic filter doesn't fails and
darkens immediately after the welding arc appears. If not,
reject it from using and contact your dealer immediately.
Don't test directly with a welding arc for security.
Recommended procedure is:
1. To use a cigarette lighter for testing automatic filter.
Only with the sparks the filter must immediately darken
in any position of the sensitivity control 15.
2. To face the welding mask against the direct sun light
and verify that filter darkens. Increase first sensitivity
control 15 between medium and high.
3. Press button 20 and the filter should darken immediately.
If it does not, refrain from using the equipment and
inform Technical Support.
Always test before use!
Sensors of the automatic darkening filter should be kept
clean and unobscured.
16