1

BOILER DESCRIPTION

1. 1

INTRODUCTION

The new "AR" series of cast iron boilers
has been designed in compliance with all
1.2

DIMENSIONS

1.3

TECHNICAL FEATURES

Output
Input
P Depth
Number of sections
Maximum water head
Water content
Smoke ∆p
Water ∆p (∆t 10°C)
Combustion capacity
Injector flow rate
Atomising angle
Atomising pressure
Weight
1.4

COMBUSTION CHAMBER DIMENSIONS

6
applicable safety standards. They use
light oil and have a perfectly balanced
combustion with a very high thermal
efficiency for economical performance.
kW
kcal/h
kW
kcal/h
mm
bar
l
mbar
mbar
kg/h
gall/h
kg/cm
2
kg
L mm
Volumen m
The components for "AR" installation
are supplied in two separate packages:
boiler body, casing with enclosed docu-
ments and control panel.
M C.H. flow
R C.H. return
S
Boiler filling drain
AR3
AR4
18.9
29.4
16,300
25,300
21.5
33.4
18,500
28,700
395
495
3
4
4
4
19
23
0. 1 0
0. 1 2
1.80
2.50
2.04
2.93
0.50
0.65
80°R
60°
8.5
12.0
92
122
AR3
AR4
277
377
3
0.013109
0.019028
1
1 /
"
2
1 /
1
"
2
1/2"
Fig. 1
AR5
40.0
34,400
45.4
39,000
595
5
4
27
0. 1 6
3.50
3.97
1.00
60°
9.7
147
AR5
477
0.024947
Fig. 2