Cooling/Ice & Water - LG LSXS22423 Serie Manual Del Usuario

Ocultar thumbs Ver también para LSXS22423 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

42
TROUBLESHOOTING
Cooling/Ice & Water
Problem
Possible Causes
Frost or ice
Condensation from food
crystals
with a high water content
on frozen
has frozen inside of the
food (inside
food package.
of sealed
Food has been left in the
package).
freezer for a long period of
time.
Icemaker is
Demand exceeds ice
not making
storage capacity.
enough ice.
House water supply is not
connected, valve is not
turned on fully, or valve is
clogged.
Water fi lter has been
exhausted.
Low house water supply
pressure.
Reverse Osmosis fi ltration
system is used.
Tubing connecting
refrigerator to house supply
valve is kinked.
Doors are opened often or
for long periods of time.
Doors are not closed
completely.
The temperature setting for
the freezer is too warm.
Solutions
This is normal for food items with a high water
content.
Do not store food items with high water content in
the freezer for a long period of time.
The icemaker will produce approximately 70-210
cubes in a 24 hour period.
Connect the refrigerator to a cold water supply with
adequate pressure and turn the water shutoff valve
fully open.
If the problem persists, it may be necessary to
contact a plumber.
Replacing the water fi lter is recommended:
Approximately every six months.
When the water fi lter indicator turns on.
When the water dispenser output decreases.
When the ice cubes are smaller than normal.
The water pressure must be between 20 and 120 psi
(
-
a) on models without a water fi lter and
between 40 and 120 psi (
with a water fi lter.
If the problem persists, it may be necessary to
contact a plumber.
Reverse osmosis fi ltration systems can reduce the
water pressure below the minimum amount and result
in icemaker issues. (Refer to Water Pressure section.)
The tubing can kink when the refrigerator is moved
during installation or cleaning resulting in reduced
water fl ow. Straighten or repair the water supply line
and arrange it to prevent future kinks.
If the doors of the unit are opened often, ambient
air will warm the refrigerator which will prevent the
unit from maintaining the set temperature. Lowering
the refrigerator temperature can help, as well as not
opening the doors as frequently.
If the doors are not properly closed, ice production
will be affected. See the Doors will not close
completely or pop open section in Parts & Features
Troubleshooting for more information.
The recommended temperature for the freezer
compartment for normal ice production is 0°F (-18ºC).
If the freezer temperature is warmer, ice production
will be affected.
a) on models

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gs68sgsGs66svs

Tabla de contenido