The Parisienne - ref. 124 03 01 - 124 05 01
2. Installation instructions
The Parisienne comes bolted to a wooden pallet with a
box over the top.
2.1. Warning to the user
All the local and national regulations, and in
particular those relating to national and European
standards, must be observed when installing the
appliance.
An incorrectly installed heating appliance can cause
serious accidents (chimney fires, burning of plastic
insulation materials, in partition walls, etc.).
The installation must comply with Current Building
Regulations. If in doubt, consult your Dealer or local
Building Inspector.
It is the installer's responsability to conform to local
building standards and requirements with regard to
installation.
The manufacturer's responsibility shall be limited to the
supply of the equipment.
2.2. Location of the unit
Ventilation :
For satisfactory appliance operation with a natural
draught, check that sufficient air for combustion is
available in the room. In this case, the residence is
under slight low pressure and a non-sealable external
air intake must be installed in addition to the chimney
itself, at least 50 cm² in section.
Chimney position :
For new chimney installations, select a central position
within the building, to provide a good heat distribution
around the building. These rooms must be at low
pressure or fitted with non-adjustable air registers,
placed so that they cannot be obstructed, to encourage
circulation of the hot air.
Hearth :
The hearth must be suitable for use with solid fuel
burning appliances and must comply with Current
Building Regulations. If in doubt, consult your Dealer or
local Building Inspector.
Rear wall and ceiling :
The appliance must not be positioned close to
combustible materials, wall & ceiling surfaces etc.,
Consult your Dealer or local Building Inspector if in
doubt.
Make sure that the floor can support the weight of the
appliance its surroundings and the hood ; In the
contrary the floor needs to be reinforced with a concrete
screed to distribute this load.
Provide adequate insulation if the floor is combustible.
4
A
6 0 0 m m
6 0 0 m m
B
6 0 0 m m
6 0 0 m m
C
1 5 0
m m
Figure 2 - Minimum clearances
The protections for the floor, it is obligatorily
non-combustible.
Position the unit to comply with the minimum
clearances to combustible material (rep. A and B,
fig. 2) and the non-combustible material (rep. C,
fig. 2). Do not place any object or combustible
material, curtains, hangings,etc inside the interior
of the appliance.
Installation instructions
1 5 0 m m