ENGLISH
Table of contents
5.0 Use ..................................................................12
7.0 Service .............................................................14
10.0 Recycling .......................................................15
Figures ..................................................................54
Register your fi replace at jotul.com for a
25-year warranty.
On all our products there is a label
Product:
Jøtul
indicating the serial number and
Room heater fired by solid fuel
Standard
:
year. Write this number in the
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
:
place indicated in the installation
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
instructions.
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number
Country
Classification
Certificate/
Approved by
standard
Norway
Klasse II
when contacting your retailer or
SP Sveriges Provnings- och
SP
Sweden
OGC
Forskningsinstitut AB
Jøtul.
SP Swedish National
Testing and Research
EUR
Intermittent
EN
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
10
Serial no.
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including thosethat refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material is located on the
heat shield at the back of the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material:
Cast iron
Finish:
Blue Black Enamel
Fuel:
Wood
Log length, max.:
55 cm
Flue outlet:
Top
Flue dimension
:
Ø 150 mm/177 cm
Hot air distributor:
Ø 150
Approx. weight:
143 kg
Options extras:
Dimensions, distances etc.: See fig.1
Technical data according to EN 13229
Nominal heat output:
Smoke gas mass flow:
Recommended chimney draught:
Effiency:
CO emission (13% O
):
2
Flue gas temperature:
Operating mode:
3.0 Safety precautions
3.1 Fire preventive measures
Any use of the fireplace may represent some danger. Therefore,
respect the following instructions:
•
Ensure that furniture and other flammable materials do not
get too close to the fireplace.
•
Let the fire die. Never put it out with water as this may
damage the product.
•
The fireplace gets warm when used and may cause burns if
touched.
•
Only remove the ashes when the stove is cold.
•
Ash must be properly disposed of outdoors, or emptied where
it does not entail a fire hazard.
2
cross
section
8,0 kW
6,4 g/s
12 Pa
73%@7,1 kW
0,20%
339
0
C
Intermittent